- #1737 Added new user permissions in keycloak.
- #1790 Added a new horizontal bypass to the plate heat exchanger 3d object.
- #1793 Added an option to make performance cases mandatory. This makes them undeletable and unable to receieve change to the selection case flag.
- #1837 The silencer 3D object now has a frame parameter to specify the depth of the individual frame walls. A zero value makes them invisible. The default splitter count is now also shown correctly.
- #1857 Fan charts are now more configurable in promaster, so you can configure which curves and labels should be shown by default. Custom colors on the pressure, power and efficiency curves and axises can be specified in
theme_colors.
- #1808 RLT locations are now defined by customers in Promaster table
rlt_locations. DLL-cloud RLT-DLL contains a base setup of locactions. It is also possible to have customised version of RLT-DLL where it is possible to upload custom and extend with addtional climate data locations.
- #331 We now use VEAB web service calculator v2 instead of own calculations. Promaster tables are updated with new tables
dll_electric_heater_type and dll_electric_heater_material, so some updates needed.
- #1807 New version of Ziehl-Abegg 2024.04.18-v1. Solves performance issue when requesting nominal and motor data.
- #1786 Honeycomb humidifiers now have the possibility to specify custom targets using
dll_humidifier_air_out.
- #1860 Fixed price calculation for klingenburg heatexchangers
- #1862 New version of Swissrotors heatexchangers 12.0.0-v1:
- HEX: CA Aluminium plates selection disabled, production stopped
- HEXWALL: HWA Aluminium plates selection disabled, production stopped
- RRG METRIC: RT-500-2400-1.6-S performance updated according to new sorption material and 2024 Eurovent Certification Campaign
- RRG IMPERIAL: SF wheels selection disabled, production stopped (all options – sorption & condensation). SF wheels certification discontinued in AHRI - SFC performance updated according to new sorption material
- #1846 Filters and dampers now support special layouts by specifying multiple grids. Syntax is the same as before, but you can now specify multiple grids separated by
+. For example the string 610/610,610+305/305,305,305,305 is one row of 2x610x610 and a second row with 4x310x310.
- #1840 Added
call column to dll_input and dll_output_corrections tables. This can be used to only apply a fix for a specific call name, as some DLLs require multiple calls to get all needed data.
Following DLL vesions will be closed 2025-06-30.
If any of theese versions are needed longer please send a request to aircalc support.
ebmpapst-fans-3.0.3.307-v1
fisair-humidifiers-3.6.6.0-v1
flakt-ekonovent-5.0.0.7-V1
hidria-fans-1.0.0.0-v1
holmak-plates-2.0.0.15-v1
hoval-heatexchangers-2.0.10.0-v1
hpmtherm-coils-9.0.0.0-v1
klingenburg-heatexchangers-0.24.0.2-v1
recuperator-heatexchangers-2.0.0.4-v1
recutech-rselect-7.2.0.12-v1
rlt-footprint-1.01-v1